To ensure you get the best experience, this website uses cookies.
        
        
     
    
                
    
        
        
        
            Large diameter cores (S7.4)
            
        
        
        
    
	- S7.4.1
- Use of large diameter cores as an excavation and reinstatement technique is permitted in unreinforced rigid roads with the following conditions:
	
		- Large diameter cores cannot be taken within 300 mm of concrete slab corners or edges. This is to protect the integrity of the concrete pavement.
- Where the technique is appropriate, it must be carried out in accordance with S6.7. To match the adjoining carriageway, between 100 mm to 150 mm of the sub-base may be removed.
 
- S7.4.2
- Large diameter cores may be used as an excavation method in continuously reinforced rigid roads. Trimming for reinstatement of the reinforcement may be required in accordance with S7.6. Re-using the excavated core is not permitted where there is a requirement to install connecting bars or lapped reinforcement.