To ensure you get the best experience, this website uses cookies.
        
        
     
    
                
    
        
        
        
        
        
    
	- A10.2.4
- Aggregates and binders for HBM must comply with BS EN 14227, the respective BS EN specified in Table A10.4 and the requirements of this clause.
	
		Table A10.4 Standards
		
			
		
		
			
				| Aggregates | BS EN 13242 |  
				| Water | BS EN 1008 |  
				| Cement | BS EN 197-1 |  
				| GBS (granulated blast furnace slag) | BS EN 14227-2 |  
				| GGBS (ground granulated blast furnace slag) | BS EN 15167-1 |  
				| Lime | BS EN 459-1 |  
				| Gypsum | BS EN 14227-2 or BS EN 14227-3 |  
				| FA (Fly ash) | BS EN 14227-4 |  
				| ASS (Air-cooled steel slag) | BS EN 14227-2 |  
				| HRB (Hydraulic road binder) | BS EN 13282 |  
 
- A10.2.5
- The binder constituent proportions must comply with Table A10.5 and must be based on a laboratory mixture design procedure in accordance with A10.2.11 to A10.2.16.
	
		Table A10.5 Minimum binder or binder constituent additions
		
			
		
		
			
				| Lime / cement / HRB / GGBS | when used with another binder constituent | 2% |  
				| when used as sole treating agent | 3% |  
				| ASS & GBS | when used together | 2.5% each |  
				| Dry fly ash | when used with cement | 4% |  
				| when used with lime | 5% |  
				| Conditioned (i.e. wet) fly ash | All applications | 6% |