To ensure you get the best experience, this website uses cookies.
        
        
     
    
                
    
        
        
        
            Areas constructed in concrete
            
        
        
        
    
	- S8.3.13
- Concrete footways, footpaths or cycle tracks must be reinstated with C25/30 minimum strength concrete, as per S7.3.2 to S7.3.4, to match the existing thickness (see Figure A7.3). For small openings, site-batched concrete of equivalent strength may be used.
- S8.3.14
- Where the authority knows of any site where air-entrained concrete has been used, it should advise undertakers in advance of the works.
- S8.3.15
- Where the existing concrete has been air-entrained, air-entrained concrete to MCHW Clause 1001 must be used. Air-entrained concrete may be used elsewhere at the discretion of the undertaker.