S6.6.10
The duct/cable must be installed in the base of the slot and held in place using clips, plugs of high density foam, or other suitable means.
S6.6.11
The finished level of the duct/cable must not vary from the agreed depth by more than 20 mm.
S6.6.12
The duct/cable must incorporate a tracer (often an integral metal wire) to facilitate detection in future.